The data should be read in conjunction with the Magnetron
Preamble and with British Standard BS9030 : 1971.
ABRIDGED DATA
Mechanically tuned pulse magnetron intended primarily for
linear accelerators.
Frequency range …… 2993 to 3002 MHz
Peak output power . . . . . . . . . . 3.1 MW
Magnet ……… electromagnet MG6053
Output . . . . . . . . . . . to no. 10 waveguide
(72.140 x 34.04 mm internal)
Isolator . . . . . . . . . . the use of an isolator is
recommended, see note 7
Cooling …………… water
GENERAL
MG6090 E2V
Electrical
Cathode ………… indirectly heated
Heater voltage (see note 1) . . . . . . 14 V dc
Heater current at 14 V . . . . . . . . 8.0 A
Heater starting current, peak value,
not to be exceeded . . . . . . . . 20 A max
Cathode pre-heating time (minimum) . . . 10 min
Mechanical
Overall dimensions . . . . . . . . . . . see outline
Net weight . . . . . . . . . . . . 8.6 kg approx
Tuner revolutions to cover frequency
range (see note 2) ……… 5.75
Mounting position (see note 3) . . . . . . . . . any
Cooling
The magnetron is water cooled and has an integral water
jacket. The recommended water flow is 5 litres per minute or
more; a pressure of approximately 1.25 kg/cm2 will be
necessary to give this rate of flow. The outlet water
temperature must not exceed 50 8C.
The cooling fins on the cathode stem must be cooled by an air
flow of at least 0.28 m3
/min.
MG6090 E2V
# e2v technologies (uk) limited 2006 A1A-MG6090 Issue 3, April 2006
181/7208
e2v technologies (uk) limited, Waterhouse Lane, Chelmsford, Essex CM1 2QU, UK Telephone: +44 (0)1245 493493 Facsimile: +44 (0)1245 492492
e-mail: enquiries@e2v.com Internet: www.e2v.com Holding Company: e2v technologies plc
e2v technologies inc. 4 Westchester Plaza, PO Box 1482, Elmsford, NY10523-1482 USA Telephone: (914) 592-6050 Facsimile: (914) 592-5148
e-mail: enquiries@e2vtechnologies-na.com
MAXIMUM AND MINIMUM RATINGS
(Absolute values)
These ratings cannot necessarily be used simultaneously, and
no individual rating should be exceeded.
Min Max
MG6090 E2V
Magnetic field (see note 4) . . . 100.0 165.0 mT
1000 1650 gauss
Heater voltage (see note 1) . . . . – 14 V dc
Heater starting current (peak) . . . – 20 A
Anode voltage (peak) . . . . . . – 52 kV
Anode current (peak) . . . . . 60 120 A
Input power (mean) . . . . . . – 8.0 kW
Pulse duration . . . . . . . . – 5.0 ms
Rate of rise of voltage pulse
(see note 5) . . . . . . . 80 120 kV/ms
Outlet water temperature . . . . – 50 8C
VSWR at the output coupler
(see note 6) …….. – 1.5:1
Pressurising of waveguide
(see note 7) . . . . . . . . – 3.1 kg/cm2 g
TYPICAL OPERATION
Operational Conditions
Magnetic field ………. 142.5 + 10 mT
MG6090 E2V
1425 + 100 gauss
Heater voltage ……….. 0 V
Anode current (peak) . . . . . . . . 102 A
Pulse duration . . . . . . . . . . . 4.3 ms
Pulse repetition rate . . . . . . 50 to 405 pps
Rate of rise of voltage pulse . . . . . 120 kV/ms
Typical Performance
Anode voltage (peak) . . . . . . . . 45 kV
Output power (peak) . . . . . . . . . 2.5 MW
Output power (mean) …….. 3.25 kW
Frequency drift . . . . . . . . . . . . see note 8
TEST CONDITIONS AND LIMITS
The magnetron is tested to comply with the following electrical
specification.
Test Conditions
Magnetic field (see note 4) …… 160.0 + 0.5 mT
1600 + 5 gauss
Heater voltage (for test) …….. 0 V
Anode current (peak) . . . . . . . . 115 A
Pulse repetition rate . . . . . . . . 200 pps
Pulse duration . . . . . . . . . . . 5.0 ms
VSWR at the output coupler …… 1.1:1
Rate of rise of voltage pulse (see note 5) . 120 kV/ms
Limits
MG6090 E2V
Min Max
Anode voltage (peak) . . . . . 46 52 kV
Output power (peak) (see note 9) . 3.0 – MW
Frequency (see notes 10 and 11):
lower end of tuning range . . . – 2993 MHz
upper end of tuning range . . 3002 – MHz
RF bandwidth at 1
/4 power . . . . – 1.2 MHz
Frequency pulling
(VSWR not less than 1.5:1) . . . – 7.0 MHz
Stability (see note 12) . . . . . – 0.5 %
Heater current . . . . . . . . . . . . see note 13
LIFE TEST
The quality of all production is monitored by the random
selection of tubes which are then life-tested under Typical
Operation Conditions. If the tube is to be operated under
conditions other than those specified herein, e2v technologies
should be consulted to verify that the life of the magnetron will
not be impaired.
End of Life Criteria
(Under the test conditions specified above)
Output power (peak) . . . . . . . . . 2.7 MW min
RF bandwidth at 1
/4 power . . . . . . . 1.2 MHz max
Frequency ……… within test limits above
Hãy là người đầu tiên nhận xét “MG6090 E2V, MG6090 Tunable S-Band Magnetron, Đại lý hãng E2V technologies Việt Nam” Hủy
Sản phẩm tương tự
ACCUMAC VIỆT NAM
ACUITY BRANDS/ ABL-nLight USA
HFX LEDHFX T8 bộ điều khiển , HFX & HFXE LED biến tần , THX SingleTHX Double
1762-IF2OF2 Allen Bradley
OPTIMASS 1400 C, CẢM BIẾN ĐO LƯU LƯỢNG OPTIMASS 1400 C, KROHNE VIỆT NAM
ĐẠI LÝ ANHYUP ELECTRONICS
Apiste Panel Cooling
F035293 Gefran ,Biến Tần F035293 , Đại lý chính thức Gefran tại Việt Nam
Đánh giá
Chưa có đánh giá nào.