Main options
Optional keypad for easy setup, commissioning, Parameterization, copy function and diagnosis
• KP500: Removable keypad
• KPCMK: Cabinet mounting kit and handheld for keypadOptional interface for communication with PC
• KP232: Serial communication interface that can be mounted & unmounted during operation, recommended for service personnel
• CM232: Serial communication interface that is installed during commissioning, recommended for continuous data logging or data exchange
• CM485: Serial communication interface that is installed during commissioning, recommended for continuous data logging or data exchange
• ISO-USB: USB to serial adapter, galvanic decoupledOptional field bus communication:
• CM-CAN: CANopen
• CM-PDP: PROFIBUS
• CM232: Modbus ASCII & Modbus RTU for point-to-point connection
• CM485: Modbus ASCII & Modbus RTU via RS485 connection
• CM-DeviceNet: DeviceNet
• CM-EtherCAT®: EtherCAT®
• CM-PROFINET: PROFINET
• CM-Ethernet/IP: Ethernet/IP with one usable port as end-of-line device
• CM-Ethernet/IP-2P: Ethernet/IP with two usable ports (daisy chaining is possible)
• CM-Modbus/TCP: Modbus/TCP with one usable port as end-of-line device
• CM-Modbus/TCP-2P: Modbus/TCP with two usable ports (daisy chaining is possible)
• Ethernet VABus/TCP: VABus/TCP: with one usable port as end-of-line device
• Ethernet VABus/TCP-2P: VABus/TCP: with two usable ports (daisy chaining is possible)Optional I/O Extension:
• EM-IO-01: Expansion for 3 digital inputs, 2 relay outputs, 1 analog input, 1 analog output, system bus connection, DC 24 V power supply output
• EM-IO-02: Expansion for 3 digital inputs, 1 relay output, 1 analog input, 1 analog output, motor-PTC input, system bus connection, DC 24 V power supply output
• EM-IO-03: Expansion for 2 digital inputs, 1 relay output, 1 analog input, 2 analog outputs, motor-PTC input, system bus connection, DC 24 V power supply output
• EM-IO-04: Expansion for 2 digital inputs, 1 digital port (input or output), motor-PTC input, system bus connection, DC 24 V power supply outputOptional encoder & feedback evaluation:
• EM-ENC-01: TTL/HTL encoder input (2 channels), encoder emulation output (2 channels), 1 analog input, system bus connection, DC 5 V power supply output
• EM-ENC-02: TTL/HTL encoder input (2 channels), 1 digital port (input or output), 1 analog input, 1 analog output, system bus connection, DC 5 V power supply output
• EM-ENC-03: TTL/HTL encoder input (2 channels), system bus connection
• EM-ENC-04: TTL/HTL encoder input (3 channels), 1 relay output, 1 analog input, 1 analog output, 24 V power supply output, DC 5 V power supply output
• EM-ENC-05: TTL/HTL encoder input (3 channels), 1 analog input, 1 analog output, system bus connection, 24 V power supply output, DC 5 V power supply output
• EM-RES-01: Resolver input, encoder emulation output (2 channels), 1 analog input, system bus connection
• EM-RES-02: Resolver input, encoder emulation output (3 channels), 1 analog input
• EM-RES-03: Resolver input, 3 digital inputs, 2 digital outputs, 1 analog input, system bus
• EM-ABS-01: Absolute encoder input (Hiperface, EnDat 2.1, SinCos), 3 digital inputs, 2 digital outputs, 1 analog input, system bus, DC 5…12 V power supply outputOptional PC software
• VPlus for Windows with motor setup, terminal monitor
• Actual value window
• Scope function
• Parameter StorageVariant for functionality extension:
• Spindle
• Winding software
• Synthetic power supplyAccessories:
• Brake resistors Type BR: Type BR: The brake resistors offer an inexpensive solution to dissipate generator power that occurs at deceleration. A thermal sensor for the brake resistor protects the resistor from overheating.
• Power choke type LCVS & LCVT: Power choke types LCVS (for single-phase power installation) and LCVT (for three-phase power installation) increase the overvoltage protection of the inverter and increase the system’s EMC.
• Power filters type FTV: Depending on the application boundaries, certain EMC levels must be achieved. The power filters are a component to improve EMC behavior in a machine installation. -
Degree of protection
IP20 (EN 60529)
-
Certifications
UL508c
STO (EN13849 / EN 61508) -
Conformity
CE
EN61800 -
Power supply & Power range
ACU410: 0.25 – 400 kW / three-phase 360 – 480V / 50 – 60 Hz (± 10%)
Parallel connection up to 1200 kWACU210: 0.25 – 9.2 kW / single or three-phase 200 – 240V / 50 – 60 Hz (± 10%)
ACU510: 160 – 400 kW / three-phase 525V / 50 – 60 Hz (± 10%)
Parallel connection up to 1200 kWACU610: 160 – 400 kW / three-phase 690V / 50 – 60 Hz (± 10%)
Parallel connection up to 1200 kW -
Output
0 … 599 Hz
-
Motors
• Motor compatibility
• Asynchronous AC motors
• Permanent magnet synchronous (brushless) motors
• Reluctance motors -
Motor options
Motor Control
Control of asynchronous, synchronous motors and synchronous reluctance motors.
Control methods:
• V/f
• Field-oriented control with encoder
• Field-oriented control without encoder
• Reluctance motor control without encoder feedback, optionally with encoder feedback
Overload capacity:
• 100 % continuous output
• up to 150 % for 60 s
• up to 200 % for 1 s
Switching frequencies 2,4,8,12,16 kHz (availability depending on power size)
EMC filter integrated up to 9.2 kW (EN61800-3)
-
TYPES & POWERS (ACU 210)
Type | Size | Power kW*
ACU 210- 01 | 1 | 0.25
ACU 210- 03 | 1 | 0.37
ACU 210- 05 | 1 | 0.55
ACU 210- 07 | 1 | 0.75
ACU 210- 09 | 1 | 1.1
ACU 210- 11 | 2 | 1.5
ACU 210- 13 | 2 | 2.2
ACU 210- 15 | 2 | 3
ACU 210- 18 | 3 | 4
ACU 210- 19 | 3 | 5.5
ACU 210- 21 | 4 | 7.5
ACU 210- 22 | 4 | 9.2 - TYPES & POWERS (ACU 410)Type | Size| Power kW*
ACU 410- 01 | 1 | 0.25
ACU 410- 03 | 1 | 0.37
ACU 410- 05 | 1 | 0.55
ACU 410- 07 | 1 | 0.75
ACU 410- 09 | 1 | 1.1
ACU 410- 11 | 1 | 1.5
ACU 410- 12 | 2 | 1.85
ACU 410- 13 | 2 | 2.2
ACU 410- 15 | 2 | 3
ACU 410- 18 | 2 | 4
ACU 410- 19 | 3 | 5.5
ACU 410- 21 | 3 | 7.5
ACU 410- 22 | 3 | 9.2
ACU 410- 23 | 4 | 11
ACU 410- 25 | 4 | 15
ACU 410- 27 | 5 | 18.5
ACU 410- 29 | 5 | 22
ACU 410- 31 | 5 | 30
ACU 410- 33 | 6 | 37
ACU 410- 35 | 6 | 45
ACU 410- 37 | 6 | 55
ACU 410- 39 | 6 | 65
ACU 410- 43 | 7 | 75
ACU 410- 45 | 7 | 90
ACU 410- 47 | 7 | 110
ACU 410- 49 | 7 | 132
ACU 410- 51 | 7 | 160
ACU 410- 53 | 7 | 200
ACU 410- 51 | 8 | 160
ACU 410- 53 | 8 | 200
ACU 410- 55 | 8 | 250
ACU 410- 57 | 8 | 315
ACU 410- 59 | 8 | 355
ACU 410- 61 | 8 | 400 -
TYPES & POWERS (ACU 510)
Type | Size | Power kW*
ACU 510- 51 | 8 | 160
ACU 510- 53 | 8 | 200
ACU 510- 55 | 8 | 250
ACU 510- 57 | 8 | 315
ACU 510- 59 | 8 | 355
ACU 510- 61 | 8 | 400 -
TYPES & POWERS (ACU 610)
Type | Size | Power kW*
ACU 610- 51 | 8 | 160
ACU 610- 53 | 8 | 200
ACU 610- 55 | 8 | 250
ACU 610- 57 | 8 | 315
ACU 610- 59 | 8 | 355
ACU 610- 61 | 8 | 400 - Sửa chữa – Cung cấp biến tần Bonfiglioli Active Cube chính hãng
- xem thêm sản phẩm https://automation.pitesvietnam.com/
- http://flowmeters-vietnam.com/
Hãy là người đầu tiên nhận xét “Sửa chữa – Cung cấp biến tần Bonfiglioli Active Cube chính hãng” Hủy
Sản phẩm tương tự
LE25CI XR1 4P-M8 HÃNG LEUZE Bộ thu cảm biến quang điện qua tia
Allen-Bradley 1492-SPM3C400 Bulletin
Đánh giá
Chưa có đánh giá nào.