TBX150F AICHI TOKEI ĐỒNG HỒ LƯU LƯỢNG TBX150F AICHI TOKEI VN
CUNG CẤP HÀNG CHÍNH HÃNG LUEZE : PITES VIỆT NAM
LH : 0916.597.556 ( Mr Tú )
TBX150F AICHI TOKEI ĐỒNG HỒ LƯU LƯỢNG TBX150F AICHI TOKEI VN
CUNG CẤP HÀNG CHÍNH HÃNG LUEZE : PITES VIỆT NAM
LH : 0916.597.556 ( Mr Tú )
The model with the correcting function (TBZ series)
Basic model | TBZ60 | TBZ150 | TBZ300 | |||||||
---|---|---|---|---|---|---|---|---|---|---|
Model name | Flow rate correcting model (with the functions of temperature and pressure correction) | – | TBZ 60-3.5 | TBZ 60-9.9 | – | TBZ 150-3.5 | TBZ 150-9.9 | – | TBZ 300-3.5 | TBZ 300-9.9 |
Actual flow rate model (without the functions of temperature and pressure) | TBZ 60-0 | – | – | TBZ 150-0 | – | – | TBZ 300-0 | – | – | |
Operating flow rate range *1 |
6~60m3/h | 12.5~150m3/h | 30~300m3/h | |||||||
Maximum operating pressure | 980kPa | 350kPa | 980kPa | 980kPa | 350kPa | 980kPa | 980kPa | 350kPa | 980kPa | |
Accuracy | Flow rate measuring parts | ±1%FS and ±3%RS | ||||||||
Operator parts and temperature and pressure correction parts | – | ±2% RSmax | ±3% RSmax | – | ±2% RSmax | ±3% RSmax | – | ±2% RSmax | ±3% RSmax | |
Display | Corrected gross accumulated flow rate (Only for the corrected flow rate model) | Large LCD in 9 digits with minimum reading of 10 L | Large LCD in 9 digits with minimum reading of 100 L | |||||||
Trip flow rate *2 | Large LCD in 8 digits with minimum reading of 10 L | Large LCD in 8 digits with minimum reading of 100 L | ||||||||
Unadjusted gross accumulated flow rate *3 | Large LCD in 9 digits with minimum reading of 10 L | Large LCD in 9 digits with minimum reading of 100 L | ||||||||
Corrected instantaneous flow rate (Only for the flow rate correction model) | LCD in 4 digits with minimum reading of 0.1 m3/h | LCD in 4 digits with minimum reading of 1 m3/h | ||||||||
Unadjusted instantaneous flow rate | LCD in 4 digits with minimum reading of 0.1 m3/h | LCD in 4 digits with minimum reading of 1 m3/h | ||||||||
Temperature (Only for the models with temperature and pressure correction) | LCD in 3 digits with minimum reading of 0.1 m3/h | |||||||||
Pressure (Only for the corrected flow rate model) | LCD in 3 digits with minimum reading of 0.1 m3/h | |||||||||
Diameters of connected parts |
JIS 10K 40A flange | JIS 10K 50A flange | JIS 10K 80A flange | |||||||
Operating temperature range | -10℃~+60℃ | |||||||||
Measurable gases *4 | Town gas, LPG, nitrogen, etc. | |||||||||
Mounting position | Horizontal and Vertical (Display supports both directions.) | |||||||||
Installation location | Indoor and outdoor * 5 | |||||||||
Case structure | Drip-proof structure, IPX 2 equivalent (JIS-CO920) | |||||||||
Power source | Built-in lithium battery | |||||||||
Output signal | Two systems of open collectors (corrected pulse and unadjusted pulse * 6) | |||||||||
Standard pulse unit width * 7 | 100 L/P Maximum load: 24 VDC and 20 mA; Pulse width: 40 msec | |||||||||
Materials | Main piping: Stainless steel; Flange: Steel; Display: Aluminum alloy | |||||||||
Temperature sensor | Platinum resistance temperature detector thermal sensor: JIS A class | |||||||||
Pressure sensor | Semiconductor type pressure sensor (High precision) | |||||||||
Mass | 5.3kg | 6.0kg | 9.4kg |
*1. Operating flow rate range is the range of the actual flow (unadjusted flow rate).. *2. Corrected trip accumulated flow rate for the flow rate correction model (with temperature and pressure correction) and unadjusted trip accumulated flow rate for the actual flow rate model (without temperature and pressure correction).. *3. Under the conditions of pressure 100 kPa or higher for the -3.5 model and 350 kPa or higher for the – 9.9 model where the temperature is at 25°C.. *4. Prevent oil mist (Carbide grade C5 or higher), dust particles and the like from entering into the meter.. *5. Avoid direct contact of water onto the meter if the meter is installed outdoors.. *6: Unadjusted pulse and high-density pulse are the actual pulse synchronized with the rotation of impellers.. *7. TBZ uses corrected pulse while TBX uses unit pulse.
Specifications of actual flow display model (TBX series)
TBX150F AICHI TOKEI ĐỒNG HỒ LƯU LƯỢNG TBX150F AICHI TOKEI VN
Model type | TBX30 | TBX100 | TBX100F | TBX150F | |
---|---|---|---|---|---|
Operating flow rate range *1 | 4~30m3/h | 10~100m3/h | 10~100m3/h | 12.5~150m3/h | |
Maximum operating pressure | 100kPa | ||||
Accuracy | Flow rate measuring parts | ±1%FS | |||
Display | Trip flow rate *2 | Large LCD in 6 digits with minimum reading of 10 L | LCD in 6 digits with minimum reading of 100 L | ||
Unadjusted gross accumulated flow rate *3 | Large LCD in 8 digits with minimum reading of 10 L | LCD in 8 digits with minimum reading of 100 L | |||
Unadjusted instantaneous flow rate | LCD in 3 digits with minimum reading of 0.1m3/h | LCD in 4 digits with minimum reading of 0.1m3/h | LCD in 3 digits with minimum reading of 1m3/h | ||
Diameters of connected parts | Rc1 1/2、Rc1 1/4 | Rc2 | JIS 10K 50A flange | ||
Operating temperature range | -10℃~+60℃ | ||||
Measurable gases *4 | Town gas, LPG, nitrogen, etc. | ||||
Mounting position | Horizontal and vertical | ||||
Installation location | Indoor | ||||
Power source | Built-in lithium battery or external power supply (24 VDC) | ||||
Output signal | Two systems of open-drain output (unit pulse and high-density pulse * 5) | ||||
Standard pulse unit width * 6 | TBX30 and TBX100: 10 L/P; TBX150: 100 L/P Maximum load: 24 VDC and 20 mA; Pulse width: 40 msec | ||||
Materials | Aluminum alloy | Cast iron | Aluminum alloy | ||
Mass | 0.8kg | 1.8kg | 7.0kg | 2.5kg |
XEM THÊM SẢN PHẨM : https://pitesvietnam.com/
Đánh giá
Chưa có đánh giá nào.