MGBS-P-L1H-AP-U-L-SA-161567 (ORDER NO. 161567)
LIÊN HỆ : 0916.597.556
MR TÚ , CUNG CẤP HÀNG CHÍNH HÃNG PITESCO VIỆT NAM
Handle modules MGBS-H-BA1A3-L-157544 (Order No. 157544)
Mechanical values and environment
| Ambient temperature | -20 … +55 °C |
| Degree of protection | IP65 |
| Installation orientation | Door hinge DIN left |
| Material | |
| Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Miscellaneous
| Additional feature | with automatic lockout mechanism |
| Product version number | V1.0.0 |
Locking modules MGBS-P-L1-AP-U-L-AZ-SA-161550 (Order No. 161550)
Work area
| Repeat accuracy R | |
| according to EN 60947-5-2 | 10 % |
Electrical connection ratings MGBS-P-L1H-AP-U-L-SA-161567
| Current consumption | |
| IIMP | 400 mA |
| IUB | 40 mA |
| Fusing | |
| external (solenoid operating voltage IMP) | 0.5 … 8 A |
| external (operating voltage UB) | 0.25 … 8 A |
| Rated insulation voltage Ui | 50 V |
| Operating voltage DC | |
| UUB | 24 V DC -15% … +15% reverse polarity protected, regulated, residual ripple < 5%, PELV |
| EMC protection requirements | according to EN IEC 60947-5-3 |
| Power consumption | 6 W |
| Rated impulse withstand voltage Uimp | 0.5 kV |
| Safety class | |
| EN IEC 61140 | III |
| Solenoid duty cycle | 100 % |
| Utilization category | |
| DC-13 | 24V 150mA |
| Solenoid operating voltage DC | |
| UIMP | 24 V DC -15% … +10% reverse polarity protected, regulated, residual ripple < 5%, PELV |
| Switching load | |
| according to UL | 24V DC, Class 2 |
| Test pulses | max. 0.3 ms |
| Test pulse interval | min. 100 ms |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Monitoring output OD, OI | |
| Output type | p-switching, short circuit-proof |
| Output voltage | 0.8xUB … UB V DC |
| Switching current | 1 … 50 mA |
| Safety outputs FO1A / FO1B | |
| Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
| Discrepancy time | |
| both safety outputs | max. 10 ms according to EN IEC 60947-5-3 |
| Off-state current Ir | max. 0.25 mA |
| Output voltage | |
| LOW U(FO1A) / U(FO1B) | 0 … 1 V DC |
| HIGH U(FO1A) / U(FO1B) | UB-1.5 … UB V DC |
| Switching current | |
| per safety output FO1A / FO1B | 1 … 150 mA |
| Turn-on time | max. 400 ms |
Mechanical values and environment MGBS-P-L1H-AP-U-L-SA-161567
| Ambient temperature | |
| at UB = 24V DC | -20 … +55 °C |
| Approach speed | max. 20 m/min |
| Connection | 1 plug connector M12, 8-pin |
| Degree of protection | IP67/IP69/IP69K |
| Extraction force | 20 N |
| Guard locking principle | Closed-circuit current principle |
| Installation orientation | Door hinge DIN left |
| Locking force Fmax | 3900 N |
| Material | |
| Switch bracket | Die-cast zinc |
| Switch head cover | Die-cast zinc |
| Safety switch housing | reinforced thermoplastic |
| Actuating force | 10 N |
| Mechanical life | 1 x 10⁶ |
| Overtravel | 5 mm |
| Ready delay | max. 1 s |
| Retention force | 20 N |
| Switching frequency | max. 0.5 Hz |
| Shock and vibration resistance | according to EN 60947-5-3 |
| Locking force FZh | 3000 N |
Reliability values according to EN ISO 13849-1
| Performance Level | PL e |
| Mission time | 20 y |
| Category | 4 |
| PFHD | 4.1 x 10 -9 |
Miscellaneous
| The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
XEM THÊM SẢN PHẨM : Cuahangtudonghoa.pitesvietnam.com



Đánh giá
Chưa có đánh giá nào.