AES 1112 SCHMERSAL HÃNG SCHMERSAL VIỆT NAM
CUNG CẤP HÀNG CHÍNH HÃNG SCHMERSAL : PITES VIỆT NAM
LH : 0916.597.556
| ||
Ordering data AES 1112 SCHMERSAL HÃNG SCHMERSAL VIỆT NAM
| ||
| Product type description | AES 1112 24 VDC | |
| Article number (order number) | 101128982 | |
| EAN (European Article Number) | 4.03066E+12 | |
| eCl@ss number, version 9.0 | 27-37-18-19 | |
| eCl@ss number, version 11.0 | 27-37-18-19 | |
| eCl@ss number, version 12.0 | 27-37-18-19 | |
| ETIM number, version 7.0 | EC001449 | |
| ETIM number, version 6.0 | EC001449 | |
| Approvals – Standards | ||
| Certificates | BG cULus EAC | |
| General data | ||
| Standards | IEC/EN 60204-1 IEC 60947-5-3 BG-GS-ET-14 BG-GS-ET-20 EN ISO 13849-1 | |
| Climatic stress | EN 60068-2-3 BG-GS-ET-14 | |
| Enclosure material | Glass-fibre reinforced thermoplastic, ventilated | |
| Material of the contacts, electrical | AgCdO | |
| Gross weight | 122 g | |
| General data – Features | ||
| Stop-Category | 0 | |
| Wire breakage detection | Yes | |
| Automatic reset function | Yes | |
| Reset after disconnection of supply voltage | Yes | |
| Integral system diagnostics, status | Yes | |
| Number of LEDs | 1 | |
| Number of normally closed (NC) | 2 | |
| Number of normally open (NO) | 1 | |
| Number of safety contacts | 1 | |
| <table><tr><td>Safety classification</td></tr></table> | ||
| Standards | EN ISO 13849-1 IEC 61508 | |
| <table><tr><td>Safety classification – Relay outputs</td></tr></table> | ||
| Performance Level, up to | c | |
| Category to EN13849 | 1 | |
| PFH value | 1.14 x 10⁻⁶ /h | |
| Notice | for max. 50,000 switching cycles/year and max. 80% contact load | |
| Safety Integrity Level (SIL), suitable for applications in | 1 | |
| Mission time | 20 Year(s) | |
| Mechanical data | ||
| Mechanical life, minimum | 10,000,000 Operations | |
| Mounting | Snaps onto standard DIN rail to EN 60715 | |
| Mechanical data – Connection technique | ||
| Type of connection | rigid or flexible Screw terminals M20 x 1.5 | |
| Terminal designations | IEC/EN 60947-1 | |
| Cable section, maximum | 2.5 mm² | |
| Tightening torque of Clips | 0.6 Nm | |
| Mechanical data – Dimensions | ||
| Width | 22.5 mm | |
| Height | 75 mm | |
| Depth | 110 mm | |
Ambient conditions AES 1112 SCHMERSAL HÃNG SCHMERSAL VIỆT NAM | ||
| Degree of protection of the enclosure | IP40 | |
| Degree of protection of the mounting space | IP54 | |
| Degree of protection of clips or terminals | IP20 | |
| Ambient temperature, minimum | +0 °C | |
| Ambient temperature, maximum | +55 °C | |
| Storage and transport temperature, minimum | -25 °C | |
| Storage and transport temperature, maximum | +70 °C | |
| Resistance to vibration to EN 60068-2-6 | 10…55 Hz, Amplitude 0.35 mm, ± 15 % | |
| Restistance to shock | 30 g / 11 ms | |
| Ambient conditions – Insulation values | ||
| Rated impulse withstand voltage Uimp | 4 kV | |
| Overvoltage category | III | |
| Degree of pollution to IEC/EN 60664-1 | 2 | |
| Electrical data | ||
| Frequency range | 50 Hz 60 Hz | |
| Thermal test current | 4 A | |
| Rated operating voltage | 24 VDC ± 15 % | |
| Rated AC voltage for controls at DC minimum | 20.4 VDC | |
| Rated control voltage at DC, maximum | 27.6 VDC | |
| Electrical power consumption | 2.4 W | |
| Contact resistance, maximum | 0.1 Ω | |
| Note (Contact resistance) | in new state | |
| Drop-out delay in case of power failure, typically | 80 ms | |
| Drop-out delay in case of emergency, typically | 20 ms | |
| Pull-in delay at automatic start, maximum, typically | 100 ms | |
| Pull-in delay at RESET, typically | 20 ms | |
Electrical data – Safe relay outputs
| ||
| Voltage, Utilisation category AC-15 | 230 VAC | |
| Current, Utilisation category AC-15 | 3 A | |
| Voltage, Utilisation category DC-13 | 24 VDC | |
| Current, Utilisation category DC-13 | 2 A | |
| Switching capacity, minimum | 10 VDC | |
| Switching capacity, minimum | 10 mA | |
| Switching capacity, maximum | 250 VAC | |
| Switching capacity, maximum | 8 A | |
| Electrical data – Digital inputs | ||
| Conduction resistance, maximum | 40 Ω | |
| Electrical data – Digital Output | ||
| Voltage, Utilisation category DC-12 | 24 VDC | |
| Current, Utilisation category DC-12 | 0.1 A | |
| Electrical data – Relay outputs (auxiliary contacts) | ||
| Switching capacity, maximum | 24 VDC | |
| Switching capacity, maximum | 2 A | |
| Electrical data – Electromagnetic compatibility (EMC) | ||
| EMC rating | EMC-Directive | |
| Status indication | ||
| Indicated operating states | Authorised operation | |
| Other data | ||
| Note (applications) | Safety sensor Guard system | |
| Note | ||
| Note (General) | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. | |
| Wiring example | ||
| Note (Wiring diagram) | The wiring diagram is shown with guard doors closed and in de-energised condition. To secure 2 guard doors up to PL c and Category 1 Monitoring 2 guard door(s), each with a magnetic safety sensor of the BNS range Monitoring one guard door: If only one magnetic safety sensor is connected to S1, the terminals S22, S32 and C of S2 must be bridged. | |